Tag Error

F2019 Motor Overtemperature Shutdown

The motor temperature measured by the temperature sensor has reached the limit value in “S-0-0204, Motor shutdown temperature”. The drive is immediately decelerated according to the selected error reaction (“P-0-0119, Best possible deceleration”) and shut down. Possible causes: Motor shutdown…

CALIBRATE LIMIT SWITCH NOT FOUND ON AXIS 0A.

During machine calibration, each axis travels to its respective limit switches (the positive or negative limit switch is determined by parameter ________).The axis will stop when the limit switch input is detected by the software. A second limit switch signal is sent to the axis servo drive amplifier which will also stop the axis movement.

SPINDLE FAULT – WINDING NOT COMPLETED ERROR.

During spindle motion, the spindle drive amplifier outputs a command to the spindle motor to rotate the spindle. On spindle drive amplifiers that have a low and high winding, the winding is automatically determined by the spindle speed command. Note that parameter ________ determines the spindle speed that the winding change occurs.