Occurs in response to failed steps during either a tool change or a requested action as part of Diagnostics.
When the ATC magazine rotates, an error can occur if the magazine does not reach a sensor in the expected amount of time or if the magazine is stopped in between stations.
Possible causes include low air or hydraulic pressure, misalignment or failure of the unclamp sensor.
When the ATC magazine rotates, an error can occur if the magazine does not reach a sensor in the expected amount of time or if the magazine is stopped in between stations.
Part Probe Fault – Unable to receive optical signal.
Part Probe battery is low.
Alarm occurs in response to failed steps during either a tool change or a requested action as part of Diagnostics.
During Tool Changes, Bore Orient cycles, Rigid Tap cycles, and Spindle Orient commands, the Spindle orients to a position to align the Spindle Drive Key to a specific angle. Typically, a proximity switch or encoder marker is used to determine the absolute position of the spindle nose, and then an offset set in the Servo Drive Amplifier is used to command the Spindle to rotate to the angle.