Machine Parameters – Overrides
Parameter |
Description |
Range |
Default |
---|---|---|---|
Sets the override minimum value. Available for Axis Feedrate, Rapid Feedrate, Spindle, or Jog unit override. |
0-100 |
0 |
|
Override Nominal (%) |
Not accessible by the user. Contact a Hurco Certified Service representative for assistance. |
|
100 |
Override Maximum (%) |
Not accessible by the user. Contact a Hurco Certified Service representative for assistance. |
|
150 |
Sets the override increment/decrement value for each override click. Available for the Axis Feedrate, Rapid Feedrate, Spindle, or Job unit override. |
Fine (1%) Coarse (5%) |
Fine (1%) |
|
Sets the behavior for a press and release of the override push button. Available for the Axis Feedrate, Rapid Feedrate, Spindle, or Jog Unit override. |
Disabled Go to Min |
Disabled |
|
Sets the behavior for a press and hold of the override push button. Available for the Axis Feedrate, Rapid Feedrate, Spindle, or Jog Unit override. |
Disabled Go to Nom Go to Min Go to Max |
Disabled |
|
Sets the override percentage change value for each click while the override push button is pressed. Available for the Axis Feedrate, Rapid Feedrate, Spindle, or Jog unit override. |
1-20 |
5 |
|
Sets the override percentage change value for each click while the override push button is not pressed. Available for the Axis Feedrate, Rapid Feedrate, Spindle, or Job unit. |
1-20 |
1 |
Override Minimum (%)
Use this parameter to set the Override Minimum percent value for the feedrate, rapid feedrate, spindle, and/or jog unit.
Select the Feed, Rapid, Spindle, or Jog tab and then enter the Override Minimum (%) value. This value cannot be greater than or equal to the maximum value.
Override Increment
Use this parameter to set the override increment/decrement value for each feedrate, rapid feedrate, spindle, and/or jog unit override click.
Select the Feed, Rapid, Spindle, or Job tab and then enter the Override Increment value.
Push Button Quick Press
Use this parameter to select the effect of pushing and quickly releasing the override button.
Select the Feed, Rapid, Spindle, or Jog tab and then select a value from the drop-down menu. Options include:
-
Disabled— disables the action.
-
Go to Minimum— overrides using the value defined in the OVERRIDE MINIMUM (%) field.
Push Button Press and Hold
Use this parameter to select the effect of pushing and holding the override button.
Select the Feed, Rapid, Spindle, or Jog tab and then select a value from the drop-down menu. Options include:
-
Disabled— disables the action.
-
Go to Nominal— overrides using the value defined in the OVERRIDE NOMINAL (%) field.
-
Go to Maximum— overrides using the value defined in the OVERRIDE MAXIMUM (%) field.
-
User Defined— overrides using the value defined in the PUSH BUTTON ON INCREMENT (%) field.
Push Button On Increment (%)
Use this parameter to set the change percent value for each override click while the override push button is pressed.
Select the Feed, Rapid, Spindle, or Jog tab and then enter the Push Button On Increment (%) value.
Push Button Off Increment (%)
Use this parameter to set the change percent value for each override clock while the override push button is not pressed.
Select the Feed, Rapid, Spindle, or Jog tab and then enter the Push Button Off Increment (%) value.