Skip to content
Mill
Lathe
How-To Guides
Search Errors / Alarms
Other Applications
Hurco Connect (Training Videos)
Service & Support
Back to HURCO.com
WinMax Help Center
Mill
Lathe
How-To Guides
Search Errors / Alarms
Other Applications
WinMax Help Center
Menu
Search Errors / Alarms
Search
Search
Error Search Result: error_notification_0067
COOLANT PRESSURE IS TOO HIGH. TOOL CANNOT BE UNCLAMPED UNTIL PRESSURE IS CORRECTED.
Definition:
Coolant pressure is too high. Tool cannot be unclamped until pressure is correct.
Tool coolant pressure is being indicated as high.
Corrective Actions:
Check wiring of coolant pressure high input.
Check for faulty connections.
Check hydraulic clamping tool for pressure leaks.
Check hydraulic pump for pressure problems.