Search Errors / Alarms

Error Search Result: error_notification_0153

ATC ERROR!! TOOL HOLDER DOWN INPUT DETECTED, EXPECTED UP INPUT. ENTER “ATC & MACHINE DIAGNOSTICS” TO CLEAR ERROR.

Definition:
ATC Error. Tool holder down input detected, expected up input. Enter “ATC & Machine diagnostics” to clear error.

Tool holder position indicates that it is in the down position when it should be in the up position.

Corrective Actions:
  • Check Tool Pocket Down input.
  • Check Tool Pocket Up input.
  • Check tool holder position indication switches are functioning properly.
  • Check for faulty or mismatched wiring.