Search Errors / Alarms

Error Search Result: error_notification_0154

ATC ERROR!! BOTH TOOL HOLDER UP AND DOWN INPUTS DETECTED. ENTER “ATC & MACHINE DIAGNOSTICS” TO CLEAR ERROR.

Definition:
ATC Error. Both tool holder up and down inputs detected. Enter “ATC & Machine diagnostics” to clear error.

Tool holder position indicates it is in both the up and down positions when only one or no positions should be indicated.

Corrective Actions:
  • Check Tool Pocket Down input.
  • Check Tool Pocket Up input.
  • Check tool holder position indication switches are functioning properly.
  • Check for faulty or mismatched wiring.