Search Errors / Alarms

Alarm Search Result for: 32787
F8013
Automatic Commutation: Current Too Low
Description:
  • Actual current value amplitude is not sufficient for exact determination of commutation offset
  • Increase signal voltage (‘P-0-0506, Amplitude for angle acquisition’ or reduce signal frequency (‘P-0-0507, Test frequency for angle acquisition’ and restart commutation setting process. – or – Enter value ‘0’ in ‘P-0-0506, Amplitude for angle acquisition’ Appropriate value for P-0-0506 is thereby automatically determined during commutation setting process. – or – Reduce value of ‘P-0-0517, Commutation: required harmonics component’, if approx. 30 similar values are determined for ‘P-0-0521, Effective commutation offset’ with repeated commutation setting for different motor positions (drive remains in ‘Ab’). Reduce ‘P-0-0517, Commutation: required harmonics component’ until command error F8013
Drive Type:
RexRoth