Search Errors / Alarms

Error Search Result: error_notification_0158

ATC ERROR!! BOTH EXCHANGE ARM AT 0 AND 60 DEGREES INPUTS DETECTED. ENTER “ATC & MACHINE DIAGNOSTICS” TO CLEAR ERROR.

Definition:
ATC Error. Both exchange arm at 0 and 60 degrees inputs detected. Enter “ATC & Machine diagnostics” to clear error.

Exchange arm detected the 0 AND 60 degree position input when the arm should be at either one or no positions.

Corrective Actions:
  • Check ATC Arm 60 Degrees input.
  • Check Spindle Alarm input.
  • Check Exchange Arm position switches are functioning properly.
  • Check for faulty wiring.