Alarm Search Result for: 33625
F8359
SMO: Encoder evaluation error
Description:
Defective encoder cable or cable shielding
Measuring system defective
Faulty mounting of measuring head in the case of linear measuring systems
Measuring system dirty
Channel 1 and channel 2 provide different data
Hardware defect on control section of drive
Check cable to measuring system and replace it, if necessary
Check measuring system and replace it, if necessary
Check mounting of measuring head and correct it, if necessary
Clean or replace measuring system
Restart drive
Replace control section or entire drive controller
Drive Type: