F8301
Error When Checking Selection Signals
Description:
  • Error in wiring: Loose connections or wire break, Incorrect wiring of inputs and outputs, Short circuit between both selection channels, Short circuit between one or both selection channels, and 24 V or 0 V
  • Delay between selection channels exceeded during a selection or deselection
  • With active safety unit: Incorrect selection (inappropriate or incorrect selection)
  • Hardware defective
  • Check wiring of selection and remove error. Then switch power supply off and on again.
  • Correct selection timing and then clear error by selecting and deselecting the safety functions. The acknowledge error message.
  • Replace safety unit
  • Replace drive controller
Drive Type: