Search Errors / Alarms

Alarm Search Result for: 33048
F8118
Invalid Power Section/Firmware Combination
Description:
  • The firmware does not support the type of power section at hand
  • In addition, IndraDrive C / IndraDrive M as of MPx-18: The hardware of the power section is outdated. The HCS02, HCS03, HCS04, HMS and HMD power sections are only supported by control section Cxx02.x if they were manufactured in 2007 or later [see indication ‘FD’ on the name plate of the power section (example: 07W49 means year 2007, week 49)]. Older hardware of these device types is no longer supported.
  • Replace firmware. Use a firmware version or a firmware release that supports the type of power section. – or – Replace the power section. Use a type of power section that is supported by the used firmware version and release. The power section may only be replaced by Rexroth service engineers. Please contact our customer service.
  • Replace the power section. Use a power section that was manufactured in 2007 or later. The power section may only be replaced by Rexroth service engineers. Please contact our customer service.
Drive Type:
RexRoth