Search Errors / Alarms
Alarm Search Result for: 32880
F8070
Control Voltage Failure
- Up to MPx16, the name of this diagnostic message was “F8070 +24Volt DC Error.”
- When this error occurs, the motors within the drive system immediately go torque-free. Possibly existing self-holding motor holding brakes apply.
- This error cannot be cleared by the error clearing command. To clear the error, the drive must be switched off completely.
Description:
- Supply cable for control voltages defective
- Overload of power supply unit for control voltage
- Power supply unit defective
- Short circuit in wiring of supply voltage
- Check and, if necessary, replace supply cable for control voltages and connector
- Check supply voltage at power supply unit
- Check and, if necessary, replace power supply unit
- Check wiring for short circuit
Drive Type:
RexRoth