F8060
Overcurrent in Power Section
This error message is generated when there is a internal signal voltage error (15v) in the power section.
Description:
External 24 V supply is not sufficiently overload-proof
Short circuit in motor or motor cable
Power section of drive controller is defective
Current loop parameterized differently
Voltage fluctuations in DC bus too high because system impedance too high
Check overload withstand capability of external 24 V power supply unit and replace it, if necessary
Check motor cable and motor for short circuit
Replace drive controller
Check current loop parameterization (cf. motor data sheet) and correct it if necessary after having contacted our service department
Reduce system impedance, e.g. increase feed wire cross sections
Drive Type:
RexRoth