Search Errors / Alarms

Alarm Search Result for: 32785
F8011
Commutation Offset Could Not be Determined
Description:
  • Axis could not carry out required motion
  • During commutation setting process, axis got into resonance
  • Motor has not been supplied with current
  • Sine-wave method without success, although axis has required freedom of motion and doesn’t show any resonance phenomena
  • Signals of motor encoder do not reflect motion process of axis; encoder cables of 2 drives possibly mixed up – or – Incorrect polarity of encoder signals
  • Check axis for stiffness or blocking; if necessary, reduce friction (lubrication, guiding device of trailing cable installation) or remove blocking – or – Set ‘search direction for sine-wave method’ to ‘increase of amplitude with priority’ in ‘P-0-0522, Control word for commutation setting’ – or – Increase value in ‘P-0-0506, Amplitude for angle acquisition’ in order to increase excitation amplitude for sine-wave method compared to frictional force of axis.
  • Set ‘search direction for sine-wave method’ to ‘increase of frequency with priority’ in ‘P-0-0522, Control word for commutation setting’ – or – Reduce value in ‘P-0-0507, Test frequency for angle acquisition’ in order modify excitation frequency for sinewave method compared to resonance frequency of axis
  • Check motor connection
  • Try with manually input values if automatic search for motorspecific values for ‘P-0-0506, Amplitude for angle acquisition’ and ‘P-0-0507, Test frequency for angle acquisition’ doesn’t provide any result in spite of several repetitions.
  • Check motor encoder signals. To do this move motor knowing manufacturer-side setting for sense of rotation or velocity polarity and check actual position values with regard to polarity and validation.
Drive Type:
RexRoth